Alarm
Alarm Name
Sub
Number
Code
51
52
53
54
55
56
57
Meaning
Cause
Zero is set for the dimension
Software operation
information "a3" for the SKR
error occurred
manipulator.
The setting of sealer-gun control-
Software operation
group parameter for the servo
error occurred
sealer control is incorrect.
The parameter setting for the
Software operation
Cartesian manipulator X-axis data
error occurred
is incorrect.
The parameter setting for the
Software operation
Cartesian manipulator Y-axis data
error occurred
is incorrect.
The setting for the Dual-arm
Software operation
manipulator is incorrect.
error occurred
Zero or a negative value is set in
Software operation
the FORMCUT maximum
error occurred
acceleration/deceleration time
parameter.
The setting of expanded check-
Software operation
point designating bits for the arm
error occurred
interference check is incorrect.
Remedy
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).