Alarm
Alarm Name
Sub
Number
Code
1349
POWER LOST
DETECTION(EAXA
01/02)
1350
POWER ON UNIT
TYPE MISMATCH
1352
SERIAL
ENCODER
CORRECTION
ERROR
Meaning
Cause
Instant power failure Check if the primary power supply voltage is dropping.
Sub Code: Signifies the axis in
Connection failure
which the alarm occurred
Connection failure
Module
failure(encoder)
Remedy
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, check the connection and insertion of the
following cables and connectors.
[Robot axis]
· Cable between encoders
· EAXA-CN508
[External axis]
· Cable between encoders
· EAXB-CN0534,535,536
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, check the connection and insertion of the
following cables and connectors.
[Robot axis]
· Cable between encoders
· EAXA-CN508
[External axis]
· Cable between encoders
· EAXB-CN0534,535,536
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the encoder.

Advertisement