Alarm
Alarm Name
Sub
Number
Code
1665
MICRO PROGRAM
SYNC. ERROR
(SV)
1666
FILE RECEIVE
INCOMPLETE
(SERVO)
1667
RESOLUTION
CONVERSE
CONST ERR(SV)
1668
CANNOT
GENERATE
GENERAL CMD
(SV)
1669
GENERAL SERVO
CMD CODE ERR
(SV)
Meaning
Cause
EAXA board failure
EAXA board failure
EAXA board failure
EAXA board failure
EAXA board failure
Remedy
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the EAXA board. Save the CMOS.BIN
before replace the board to be safe.
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the EAXA board. Save the CMOS.BIN
before replace the board to be safe.
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the EAXA board. Save the CMOS.BIN
before replace the board to be safe.
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the EAXA board. Save the CMOS.BIN
before replace the board to be safe.
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the EAXA board. Save the CMOS.BIN
before replace the board to be safe.