Download Print this page

YASKAWA DX100 Maintenance Manual page 255

Hide thumbs Also See for DX100:

Advertisement

Alarm
Alarm Name
Sub
Number
Code
9
10
11
Meaning
Cause
Unable to send a request to
YCP01 board failure (1)Turn the power OFF then back ON.
initialize the arithmetic section
(ARITH)
Software operation
error occurred
Unable to initialize ARITH
YCP01 board failure (1)Turn the power OFF then back ON.
Software operation
error occurred
Unable to send a request to
YCP01 board failure (1)Turn the power OFF then back ON.
prepare the current position
Software operation
error occurred
Remedy
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
remove the CF from the failure YCP01 board to insert it into the new YCP01
board.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
remove the CF from the failure YCP01 board to insert it into the new YCP01
board.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
remove the CF from the failure YCP01 board to insert it into the new YCP01
board.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).