Download Print this page

YASKAWA DX100 Maintenance Manual page 191

Hide thumbs Also See for DX100:

Advertisement

Alarm
Alarm Name
Sub
Number
Code
10
11
Meaning
Cause
The station No. specified by the
Setting error
DeviceNet allocation file2 is
incorrect (the station No. is out of
the allowable range, or the
specified station board is not the
DeviceNet master).
YCP01 board failure (1)Turn the power OFF then back ON.
YIF board failure
The MAC_ID specified by the
Setting error
DeviceNet allocation file2 is not
consistent with the MAC_ID of the
specified station board.
YCP01 board failure (1)Turn the power OFF then back ON.
Remedy
(1)Check the following settings.
[XFB01 board]
· The settings of the objective DeviceNet allocation file
· The I/O module settings of the objective DeviceNet board in maintenance
mode
· The DeviceNet allocation of the I/O module in maintenance mode
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
remove the CF from the failure YCP01 board to insert it into the new YCP01
board.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YIF01 board, and then load
the CMOS.BIN saved before alarm occurred.
(1)Check the following settings.
[XFB01 board]
· The settings of the objective DeviceNet allocation file
· The I/O module settings of the objective DeviceNet board in maintenance
mode
· The DeviceNet allocation of the I/O module in maintenance mode
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
remove the CF from the failure YCP01 board to insert it into the new YCP01
board.

Advertisement

loading