Guide to insert AP Kit
[Cleaning Timing]
Perform cleaning every time AP Kit is removed and inserted.
[Cleaning Location]
Clean the vicinity[c] of each dowel[b] attached to the guide[a] on the machine side, in the area where AP Kit
is to be inserted.
[Caution]
Be careful not to drop the dowels during cleaning.
<Works related to AP Kit removal>
- The drum edges are cleaned at every 250 thousand sheets.
- The entire drum surface is cleaned at every 300 thousand sheets.
- The drum cleaning blade movement is reversed at every 300 thousand sheets (1-sided).
- The drum front/rear side seals are replaced at every 500 thousand sheets.
- The drum separation claws are replaced at every 500 thousand sheets.