Canon imageRUNNER ADVANCE 8105 Series Manual page 128

Symptoms & solutions
Hide thumbs Also See for imageRUNNER ADVANCE 8105 Series:
Table of Contents

Advertisement

Field Remedy
When the symptom occurred, following the procedure below, replace the separation claw holder with the
new type one [C] with which the range of movement of the separation claw is narrowed. The photo [B]
shows the old type of the separation claw holder (FC9-4860-000).
1) Remove the AP kit assembly [1] from the main body.
2) Remove the drum and cover it with paper, etc. to protect it from exposure.
3) Remove the 2 E-rings attached to the shaft [6].
4) Slide the shaft [6] to the direction of the arrow [D] until it hits the far end.
pg. 128