YASKAWA V1000 Quick Start Manual page 77

Compact vector control drive
Hide thumbs Also See for V1000:
Table of Contents

Advertisement

9.
Press the
key until back at the Top Screen.
Enter Data from the Motor Nameplate
After selecting the type of Auto-Tuning, enter the required data from the motor nameplate.
Note: These instructions continue from Step 7 in Selecting the Type of Auto-Tuning.
1.
Press
to access the motor output power parameter T1-02.
2.
Press
to view the default setting.
3.
Press
to select the digit to edit.
Press
and enter "0.2." Enter value based on motor
4.
nameplate data.
5.
Press
to save the setting.
6.
The display automatically returns to the screen shown in Step 1.
Repeat Steps 1 through 5 to set the following parameters:T1-03,
Motor Rated Voltage T1-04, Motor Rated CurrentT1-05, Motor Base
7.
FrequencyT1-06, Motor Poles;
T1-07, Motor Base Frequency
Note: For the details of each setting, . For stationary Auto-Tuning for line-to-line resistance only, set
T1-02 and T1-04.
Starting Auto-Tuning
WARNING! Sudden Movement Hazard. The drive and motor may start unexpectedly during Auto-Tuning,
which could result in death or serious injury. Ensure the area surrounding the drive motor and load are clear
before proceeding with Auto-Tuning.
YASKAWA ELECTRIC TOEP C710606 14A YASKAWA AC Drive - V1000 Quick Start Guide
Step
Step
4.6 Test Run
Display/Result
Display/Result
4
77

Advertisement

Table of Contents
loading

Table of Contents