No.
Name
Frequency Reference Accel/Decel
d4-04
(Up/Down 2)
Frequency Reference Bias Operation
d4-05
Mode Selection
(Up/Down 2)
Frequency Reference Bias
d4-06
(Up/Down 2)
Analog Frequency Reference
d4-07
Fluctuation Limit (Up/Down 2)
Frequency Reference Bias Upper
d4-08
Limit (Up/Down 2)
Frequency Reference Bias Lower
d4-09
Limit (Up/Down 2)
d7-01 Offset Frequency 1
d7-02 Offset Frequency 2
d7-03 Offset Frequency 3
E1-01 Input Voltage Setting
E1-03 V/f Pattern Selection
E1-04 Max Output Frequency (FMAX)
E1-05 Max Voltage (VMAX)
E1-06 Base Frequency (FA)
E1-07 Mid Output Freq. (FB)
E1-08 Mid Output Frequency Voltage (VC) Only applicable when E1-03 is set to F.
E1-09 Minimum Output Freq. (FMIN)
Minimum Output Freq. Volt.
E1-10
(VMIN)
E1-11 Mid Output Frequency 2
E1-12 Mid Output Frequency Voltage 2
E1-13 Base Voltage (VBASE)
YASKAWA ELECTRIC TOEP C710606 14A YASKAWA AC Drive - V1000 Quick Start Guide
0: Adjusts bias value according to currently selected accel/decel time.
1: Adjusts the bias value by Accel/Decel Time 4 (C1-07 and C1-08).
0: Holds the bias value when Up/Down 2 reference is on or off.
1: When the Up 2 reference and Down 2 reference are both on or both
off, applied bias becomes 0 using currently selected accel/ decel.
times.
Saves the bias value once the frequency reference is adjusted.
When the Up 2 and Down 2 commands are enabled, the frequency
reference holds the bias value as the levels for the analog frequency
reference or pulse train frequency reference change, accelerating or
When d4-06 is greater than d4-08, d4-08 becomes bias for upper
limit.
When d4-06 is less than d4-09, d4-09 becomes bias for lower limit.
d7: Offset Frequency
Use d7 parameters to set the offset frequency.
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
E1: V/f Pattern Characteristics
Use E1 parameters to set V/f characteristics for the motor.
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
Only applicable when E1-03 is set to F.
Only applicable when E1-03 is set to F.
Only applicable when E1-03 is set to F.
Only applicable when E1-03 is set to F. To set linear V/f
characteristics, set the same values for E1-07 and E1-09.
Only applicable when E1-03 is set to F. To set linear V/f
characteristics, set the same values for E1-07 and E1-09.
Only applicable when E1-03 is set to F.
Only applicable when E1-03 is set to F.
Only applicable when E1-03 is set to F.
Only applicable when E1-03 is set to F.
7.1 Parameter Table