6.2 Single/Three-Phase 200 V Class Drive
<3> Input current rating varies depending on the power supply transformer, input reactor, wiring connections, and
power supply impedance.
<4> Rated motor capacity is calculated with a rated output voltage of 230 V.
<5> Carrier frequency is set to 2 kHz. Current derating is required in order to raise the carrier frequency.
<6> Carrier frequency is set to 10 kHz. Current derating is required in order to raise the carrier frequency.
<7> Carrier frequency is set to 8 kHz. Current derating is required in order to raise the carrier frequency.
Three-Phase: CIMR-V 2A
Single-Phase: CIMR-V BA
Maximum Motor Size Allowed (HP)
Input Current
Input
(A)
<3>
Rated Output Capacity
(kVA)
Output Current (A)
Output
Max Output Frequency (Hz)
Power
Supply
Allowable Voltage Fluctuation
Allowable Frequency Fluctuation
Harmonic Countermeasures
Heat Generation (W)
<1> Drives with single-phase power supply inputs output three-phase power, and cannot run a single-phase motor.
108
Table 6.3 Power Ratings Continued
Item
<1>
ND Rating
<2>
HD Rating
ND Rating
Three-Phase
HD Rating
ND Rating
Single-Phase
HD Rating
ND Rating
<4>
HD Rating
ND Rating
HD Rating
Overload Tolerance
Carrier Frequency
Max Output Voltage (V)
Rated Voltage
Rated Frequency
DC
Reactor
ND Rating
Three Phase
HD Rating
ND Rating
Single Phase
HD Rating
YASKAWA ELECTRIC TOEP C710606 14A YASKAWA AC Drive - V1000 Quick Start Guide
0030
0040
-
10.1
14.8
7.4
10.1
34.7
50.9
26.0
35.4
-
-
11.4
15.2
9.5
12.6
30.0
40.0
<5>
25.0
33.0
<7>
ND Rating: 120% of rated output current for 1 minute
HD Rating: 150% of rated output current for 1 minute
(Derating may be required for applications that start and
2 kHz (user-set, 2 to 15 kHz)
Three-phase power: Three-phase 200 to 240 V
Single-phase power: Three-phase 200 to 240 V (both
proportional to input voltage)
400 Hz (user-adjustable)
Three-phase power: Three-phase 200 to 240 V 50/60 Hz
Single-phase power: 200 to 240 V 50/60 Hz
-
335.3
379.5
303.7
321.3
-
Specification
0056
-
-
20.1
14.8
69.4
51.9
-
-
-
-
21.3
17.9
56.0
47.
<7>
<7>
stop frequently)
-15 to 10%
±5%
Optional
-
-
509.7
465.2
-
-
0069
-
24.8
20.1
85.6
70.8
-
-
26.3
22.9
69.0
60.0
<7>
-
646.2
589.1
-