YASKAWA V1000 Quick Start Manual page 115

Compact vector control drive
Hide thumbs Also See for V1000:
Table of Contents

Advertisement

No.
Name
Run Command Selection while in
b1-08
Programming Mode
b1-14 Phase Order Selection
b1-15 Frequency Reference 2
b1-16 Run Command Source 2
b1-17 Run Command at Power Up
DC Injection Braking Start
b2-01
Frequency
b2-02 DC Injection Braking Current
DC Injection Braking Time/DC
b2-03
Excitation Time at Start
b2-04 DC Injection Braking Time at Stop
Magnetic Flux Compensation
b2-08
Capacity
b2-12 Short Circuit Brake Time at Start
b2-13 Short Circuit Brake Time at Stop
Use B3 parameters to configure Speed Search function operation.
b3-01 Speed Search Selection
b3-02 Speed Search Deactivation Current
b3-03 Speed Search Deceleration Time
b3-05 Speed Search Delay Time
Output Current 1 during Speed
b3-06
Search
Speed Search Detection
b3-10
Compensation Gain
Bi-Directional Speed Search
b3-14
Selection
b3-17 Speed Search Restart Current Level
b3-18 Speed Search Restart Detection Time Refer to V1000 Technical Manual for details.
b3-19 Number of Speed Search Restarts
b3-24 Speed Search Method Selection
YASKAWA ELECTRIC TOEP C710606 14A YASKAWA AC Drive - V1000 Quick Start Guide
0: Run command accepted only in the operation menu.
1: Run command accepted in all menus.
2: Prohibit entering programming mode during Run
Sets phase order for drive output terminals U/T1, V/T2 and W/T3.
0: Standard
1: Switch phase order
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
b2: DC Injection Braking
Use b2 parameters to configure DC Injection Braking operation
Refer to V1000 Technical Manual for details.
Sets the DC Injection Braking current as a percentage of the drive
rated current.
Sets DC Injection Braking time at start. Disabled when set to 0.00
seconds.
Sets DC Injection Braking time at stop.
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
b3: Speed Search
Refer to V1000 Technical Manual for details.
Sets the current level at which the speed is assumed to be detected
and Speed Search is ended. Set in percent of the drive rated current.
Sets time constant used to reduce the output frequency during speed
search. Related to a change from max. output frequency to 0.
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
7.1 Parameter Table
Description
7
115