Item
CIMR-V 4A
Maximum Applicable Motor Capacity
(HP)
<1>
Input
Input Current (A)
Output Current (kVA)
Output Current (A)
Output
Overload Tolerance
Carrier Frequency
Maximum Output Voltage (V)
Maximum Output Frequency (Hz)
Rated Voltage Rated Frequency
Power
Allowable Voltage Fluctuation
Supply
Allowable Frequency Fluctuation
Harmonic
Countermeasures
Heat Generation (W)
<1> The motor capacity (kW) refers to a Yaskawa 4-pole motor. The rated output current of the drive output amps
should be equal to or greater than the motor rated current.
<2> .Input current rating varies depending on the power supply transformer, input reactor, wiring conditions, and
power supply impedance.
<3> Rated motor capacity is calculated with a rated output voltage of 440 V.
<4> Carrier frequency is set to 2 kHz. Current derating is required in order to raise the carrier frequency.
<5> Carrier frequency is set to 8 kHz. Current derating is required in order to raise the carrier frequency.
Note: Differences between Heavy Duty ratings and Normal Duty ratings for the drive include rated
input and output current, overload capacity, carrier frequency, current limit, and maximum
output frequency. Set parameter C6-01 to "0" for Heavy Duty ratings or "2" for Normal Duty
ratings. The default is Normal Duty (C6-01 = 1).
YASKAWA ELECTRIC TOEP C710606 14A YASKAWA AC Drive - V1000 Quick Start Guide
6.3 Three-Phase 400 V Class Drives
Table 6.5 Power Ratings Continued
ND Rating
HD Rating
ND Rating
<2>
HD Rating
ND Rating
<4>
<3>
HD Rating
<5>
ND Rating
<4>
HD Rating
<5>
<3>
DC Reactor
ND Rating
HD Rating
Specification
0018
0023
10.1
14.8
7.4
10.1
20.0
24.0
15.0
20.0
13.3
17.5
11.3
13.7
17.5
23.0
14.8
18.0
ND Rating: 120% of rated output current for 60 s
HD Rating: 150% of rated output current for 60 s
(Derating may be required for applications that start and
stop frequently)
2 kHz (user-adjustable from 2 to 15 kHz)
Three-phase: @380 to 480 V (proportional to input
voltage)
400 Hz (user-adjustable)
Three-phase: 380 to 480 V 50/60 Hz
-15 to 10%
±5%
Optional
261.3
321.1
228.7
285.2
0031
0038
20.1
24.8
14.8
20.1
38.0
44.0
29.0
39.0
23.6
29.0
18.3
23.6
31.0
38.0
24.0
31.0
433.6
475.0
372.8
445.7