No.
Name
Cumulative Operation Time at 8th
U3-18
Most Recent Fault
Cumulative Operation Time at 9th
U3-19
Most Recent Fault
Cumulative Operation Time at
U3-20
10th Most Recent Fault
U4-01
Accumulated Operation Time
U4-02
Number of Run Commands
U4-03
Cooling Fan Operation Time
U4-05
Capacitor Maintenance
U4-07
IGBT Maintenance
U4-09
LED Check
U4-10
kWH, Lower 4 Digits
U4-11
kWH, Upper 5 Digits
U4-13
Peak Hold Current
U4-14
Peak Hold Output Frequency
U4-16
Motor Overload Estimate (OL1)
Frequency Reference Source
U4-18
Selection
Frequency Reference from
U4-19
MEMOBUS/Modbus Comm.
U4-20
Option Frequency Reference
U4-21
Run Command Source Selection
MEMOBUS/Modbus
U4-22
Communications Reference
U4-23
Option Card Reference
U5-01
PID Feedback
U5-02
PID Input
U5-03
PID Output
U5-04
PID Setpoint
U5-05
PID differention feedback
U5-06
PID Adjusted Feedback
U6-01
Motor Secondary Current (Iq)
YASKAWA ELECTRIC TOEP C710606 14A YASKAWA AC Drive - V1000 Quick Start Guide
Displays the cumulative operation time at the eighth most recent fault.
Displays the cumulative operation time at the ninth most recent fault.
Displays the cumulative operation time at the tenth most recent fault.
U4: Maintenance Monitors
Use U4 parameters to display drive maintenance information.
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
Monitors the drive output power.
Displays the peak hold current during run.
Refer to V1000 Technical Manual for details.
100% = OL1 detection level
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
U5: Application Monitor
Use U5 parameters to view application-specific settings.
Displays the PID feedback value in.
Refer to V1000 Technical Manual for details.
Displays PID control output.
Displays the PID setpoint.
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
U6: Application Monitor
Use U6 parameters to display drive control information.
Refer to V1000 Technical Manual for details.