3.2 Main Circuit Wiring
Table 3.9 Wire Size and Torque Specifications (Same for All Models)
Tightening
Screw
Terminal
Size
MA, MB,
M3
MC
S1-S7, SC,
RP, +V, A1,
A2, AC, HC,
H1, P1, P2,
M2
PC, MP,
AM, AC,
S+, S-, R+,
R-, IG
Ferrule-Type Wire Terminations
Crimp a ferrule to signal wiring to improve wiring simplicity and reliability. Use
CRIMPFOX ZA-3, a crimping tool manufactured by PHOENIX CONTACT.
Figure 3.6
Size mm
(AWG)
2
0.25 (24)
0.34 (22)
0.5 (20)
0.75 (18)
1.0
42
Tightening
Torque
Torque
N m
(in-lbs)
0.5 to 0.6
4.4 to 5.3
0.22 to 0.25
1.9 to 2.2
Figure 3.6 Ferrule Dimensions
Table 3.10 Ferrule Terminal Types and Sizes
Type
L (mm)
AI 0.25-6YE
10.5
AI 0.34-6TQ
10.5
AI 0.5-6WH
12
A1 0.75-6GY
12
AI 1-6RD
12
YASKAWA ELECTRIC TOEP C710606 14A YASKAWA AC Drive - V1000 Quick Start Guide
Bare Wire Terminal
Applicable wire
Recomm.
size
mm
mm
2
(AWG)
(AWG)
Stranded: 0.25 to
1.5 (24 to 16)
0.75 (18)
Single: 0.25 to
1.5 (24 to 16)
Stranded: 0.25 to
1.0 (24 to 18)
0.75 (18)
Single: 0.25 to
1.5 (24 to 16)
φd1
φd2
d1 (mm)
d2 (mm)
0.8
2
0.8
2
1.1
2.5
1.3
2.8
1.5
3.0
Ferrule-Type Terminal
Applicable
Recomm.
wire size
2
mm
mm
2
(AWG)
(AWG)
0.25 to 1.0
0.5 (20)
(24 to 18)
0.25 to 0.5
0.5 (20)
(24 to 20)
Manufacturer
PHOENIX CONTACT
Wire
Type
2
Shielded
line, etc.