7.1 Parameter Table
H1-
Function
Setting
20 to 2F External Fault
30
PID Integral Reset
31
PID Integral Hold
32
Multi-Step Speed Reference 4
34
PID Soft Starter
35
PID Input Switch
Forward Run Command
40
(2-wire sequence)
Reverse Run Command
41
(2-wire sequence)
Run Command (2-wire
42
sequence 2)
FWD/REV Command (2-wire
43
sequence 2)
44
Offset Frequency 1 Addition
45
Offset Frequency 2 Addition
46
Offset Frequency 3 Addition
DC Injection Braking
60
Command
61
External Search Command 1
62
External Search Command 2
65
KEB Ride-Thru 1 (N.C.)
126
H1 Multi-Function Digital Input Selections
20: N.O., Always Detected, Ramp To Stop
21: N.C., Always Detected, Ramp To Stop
22: N.O., During Run, Ramp To Stop
23: N.C., During Run, Ramp To Stop
24: N.O., Always Detected, Coast To Stop
25: N.C., Always Detected, Coast To Stop
26: N.O., During Run, Coast To Stop
27: N.C., During Run, Coast To Stop
28: N.O., Always Detected, Fast-stop
29: N.C., Always Detected, Fast-stop
2A: N.O., During Run, Fast-stop
2B: N.C., During Run, Fast-stop
2C: N.O., Always Detected, Alarm Only (continue running)
2D: N.C., Always Detected, Alarm Only (continue running)
2E: N.O., During Run, Alarm Only (continue running)
2F: N.C., During Run, Alarm Only (continue running)
Closed: Resets the PID control integral value.
Closed: Maintains the current PID control integral value.
Used to select Multi-Step Speeds set in d1-01 to d1-16
Closed: Disables the PID soft starter b5-17.
Closed: Inverses the PID input signal
Open: Stop
Closed: Forward run
Open: Stop
Closed: Reverse run
Open: Stop
Closed: Run
Open: Reverse
Closed: Forward
Closed: Adds d7-01 to the frequency reference.
Closed: Adds d7-02 to the frequency reference.
Closed: Adds d7-03 to the frequency reference.
Closed: Triggers DC Injection Braking (b2-02)
Closed: Activates Current Detection Speed Search from the max. output
frequency (E1-04) if b3-01=0.
Closed: Activates Current Detection Speed Search from the frequency
referecne if b3-01=0. Activates Speed Estimation Type Speed search if
b3-01 =1.
Open: KEB Ride-Thru 1 enabled
Closed: Normal operation
YASKAWA ELECTRIC TOEP C710606 14A YASKAWA AC Drive - V1000 Quick Start Guide