YASKAWA V1000 Quick Start Manual page 134

Compact vector control drive
Hide thumbs Also See for V1000:
Table of Contents

Advertisement

7.1 Parameter Table
No.
Motor Acceleration Time for
L3-24
Inertia Calculations
L3-25
Load Inertia Ratio
Speed Agreement Detection Level These parameters configure the multi-function output (H2-
L4-01
L4-02
Speed Agreement Detection Width
Speed Agreement Detection Level
L4-03
(+/-)
Speed Agreement Detection Width
L4-04
(+/-)
Frequency Reference Loss
L4-05
Detection Selection
Frequency Reference at Reference
L4-06
Loss
L4-07
Frequency Detection Conditions
L5-01
Number of Auto Restart Attempts
L5-02
Auto Restart Operation Selection
L5-04
Fault Reset Interval Time
L5-05
Fault Reset Operation Selection
L6-01
Torque Detection Selection 1
L6-02
Torque Detection Level 1
L6-03
Torque Detection Time 1
L6-04
Torque Detection Selection 2
L6-05
Torque Detection Level 2
L6-06
Torque Detection Time 2
134
Name
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
L4: Frequency Detection
Use L4 parameters to configure frequency detection operation.
4, 5) settings "Fref/Fout Agree 1", "Fref/Set Agree 1", "Frequency
Detection 1," and "Frequency detection 2".
Refer to V1000 Technical Manual for details.
0: Stop - Drive will stop
1: Run at L4-06
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
Use L5 parameters to configure Automatic Restart after fault.
Sets the counter for the number of times the drive attempts to restart
when the following faults occur: GF, LF, OC, OV, PF, PUF, RH, RR,
OL1, OL2, OL3, OL4, UV1.
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
L6: Overtorque Detection
Use L6 parameters to configure overtorque detection.
0: Disabled
1: OL3 at Speed Agree - Alarm
2: OL3 at RUN - Alarm
3: OL3 at Speed Agree - Fault
5: UL3 at Speed Agree - Alarm
6: UL3 at RUN - Alarm .
7: UL3 at Speed Agree - Fault
8: UL3 at RUN - Fault .
Sets the overtorque/undertorque detection level.
Sets the length of time an overtorque/undertorque condition must exist
before Torque Detection 1 is triggered.
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
YASKAWA ELECTRIC TOEP C710606 14A YASKAWA AC Drive - V1000 Quick Start Guide
L5: Fault Reset
Description
= 2, 3,

Advertisement

Table of Contents
loading