▶ Choose one of the following options from the update tool menu to start the
iRMC update process:
Normal:
Choose this option to update an existing system board.
Initial:
Choose this option if the system board has been replaced prior to the iRMC
update procedure. This option will perform all relevant flash procedures in a
row, including the iRMC firmware and bootloader.
CAUTION
If the process is interrupted, the iRMC may be permanently
corrupted.
▶
Do not interrupt the iRMC upgrade process after it has started.
If the iRMC does not work after flashing, disconnect the system from
the mains and reconnect it again.
▶ After completion of the flash process, remove the USB stick and restart the
server.
iRMC recovery procedure
▶ Prepare an USB stick including the bootable iRMC firmware update image.
▶ Ensure that the server has been shut down and disconnected from the
mains, see
"Disconnecting the power cord" on page
▶ Connect the USB stick containing the iRMC firmware to an USB port.
▶ Connect the server to the mains while pushing the ID button on the front
panel. Ask a second person to help you if necessary.
▶ Ensure that the Global Error indicator and the ID indicator are flashing to
indicate that the server is entering the iRMC recovery state.
▶ Press the Power On/Off button. The system will start the POST process.
▶ During POST, press [F12] and select the connected USB stick as boot
device. The system will detect the USB stick.
RX1330 M5
Upgrade and Maintenance Manual
Basic software procedures
47.
75