Fujitsu PRIMERGY RX1330 M5 Upgrade And Maintenance Manual page 144

Table of Contents

Advertisement

Hard disk drive (HDD) / solid state disk (SSD)
Tools:
– Installation frame included: tool-less
– Installation frame excluded: Phillips PH1 / (+) No. 1 screw driver
This procedure is also valid for PCIe SSD modules, because this server
has no onboard NVMe controller and the PCIe SSD modules are
controlled by a RAID controller.
CAUTION
Only remove an HDD/SSD module during operation if the drive is
not currently being accessed. Observe the indicators on the
corresponding HDD/SSD module, see
HDD/SSD module" on page
An HDD/SSD module can be replaced while the system is in
operation. RAID configuration with a RAID controller:
● Modular Host Bus Adapter with "Integrated RAID" (IR). RAID
levels 0 and 1 are supported for internal HDD configurations.
● Modular RAID 0/1 controller with "MegaRAID functionality"
(integrated MegaRAID). RAID levels 0, 1, 10, 5 and 50 are
supported for internal HDD configurations.
● Modular RAID 5/6 controller with "MegaRAID functionality"
(MegaRAID). RAID levels 0, 1, 10, 5, 50, 6 and 60 are supported
for internal HDD configurations. As an option, a flash backup unit
(FBU) can save the memory content even if the power fails.
Cache memory size of up to 8 GB is available.
An HDD/SSD module can be replaced while the system is in
operation. RAID configuration without a RAID controller:
Please follow the instruction of each software e.g. VSAN, Storage
Spaces, and Storage Spaces Direct, provided separately to use the
software RAID function of OS or Hypervisor.
All HDD/SSD modules (drives) must be uniquely identified so that
they can be reinstalled in their original bays later. If this is not done,
existing data can be lost.
144
353.
Upgrade and Maintenance Manual
"Indicators on the hot-plug
RX1330 M5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents