Fujitsu PRIMERGY RX1330 M5 Upgrade And Maintenance Manual page 146

Table of Contents

Advertisement

Hard disk drive (HDD) / solid state disk (SSD)
Preliminary steps
"Locating the defective server" on page
▶ If applicable,
"Removing the front cover with lock" on page
"Shutting down the server" on page
"Connecting the power cord" on page
"Getting access to the component" on page
▶ Release all HDD/SSD modules and pull them out a few centimeters, see
"Removing a 2.5-inch HDD/SSD module" on page
CAUTION
The HDD/SSD modules need not to be removed.
If you want to remove them nevertheless, check if all HDD/SSD
modules are uniquely identified so that you can reinsert them
into their original bays.
▶ Release all dummy modules and pull them out a few centimeters, see
"Removing a 2.5-inch HDD/SSD module" on page
Removing the left side 4x 2.5-inch HDD backplane
Figure 75: Releasing the ODD
▶ If applicable, disconnect the ODD cables (1).
▶ If applicable, press the ODD latch downward (2) until it disengages and
push the ODD somewhat in direction of the front side (3).
146