480 Legend Series Weight Indicator
3.2.6

Digital Input Menu

CONFIG
FORMAT
Parameter
Choices
DIGIN1
--
DIGIN2
OFF
DIGIN3
ZERO
DIGIN4
TARE
NT-GRS
UNITS
DSPTAR
PRINT
CLRCN
KBDLOC
HOLD
CLRTAR
ACCUM
CLRACC
BATSTR
BATSTP
BATRES
BATPUS
BATRUN
NET
GROSS
PRI
SEC
www.RiceLake.com
42
Visit our website
CALIBR
PROGRM
DIG IN
DIGIN1-4
OFF
ZERO
TARE
NT-GRS
UNITS
DPSTAR
PRINT
CLRCN
Figure 3-14. Digital Input Menu
Specifies the function activated by digital inputs 1, 2, 3 and 4
Sets the Digital Input to perform no function
Same function as the front panel key
Same function as the front panel key
Net-Gross – same function as the front panel key
Same function as the front panel key
Displays the current tare value
Same function as the front panel key
Resets the consecutive number to the value specified on the CONSTU parameter (PROGRM menu)
Disables the keypad while the digital input is held active
Holds the current display; releasing this input returns to normal display update mode
Clears the tare
Displays the accumulator
Clears the accumulator
Starts a batch process
Stops a batch; a restart starts the batch at the beginning
Resets the batch process; the pointers are aimed at first batching setpoint
Pauses a batch, but allows it to restart at the point where it was paused
A switch that allows a batch to be started. It must be active to allow a batch to run; if not active, and
a BATSTRT input is activated, the batch will abort or reset
Puts the scale in net mode
Puts the scale in gross mode
Puts the scale in primary units
Puts the scale in secondary units
Table 3-15. Digital Input Menu Parameters
ALGOUT
PASWRD
USBMEM
KBDLOC
HOLD
CLRTAR
ACCUM
CLRACC
BATSTR
BATSTP
BATRES
Description
TEST
MENU
BATPUS
BATRUN
NET
GROSS
PRI
SEC