3.2.7

Digital Input Menu

DIG IN Menu
Parameter
Choices
Level 2 submenus
DIGIN1
OFF
DIGIN2
ZERO
TARE
NT/GRS
UNITS
DSPTAR
PRINT
CLRCN
KBDLOC
HOLD
22
IQ plus 355 Installation Manual
Figure 3-11. Digital Input Menu
Specifies the function activated by digital inputs 1 and 2.
• ZERO, NT/GRS (net/gross mode toggle), TARE, UNITS, and PRINT provide the same
functions as the front panel keys.
• DSPTAR displays the current tare value.
• CLRCN resets the consecutive number to the value specified on the CONSTU parameter
(PROGRM menu).
• KBDLOC disables the keypad while the digital input is held low.
• HOLD holds the current display. Releasing this input clears the running average filter.
Table 3-7. Digital Input Menu Parameters