Digital Input Menu - Rice Lake 520 Installation Manual

Digital weight indicator
Table of Contents

Advertisement

3.2.8

Digital Input Menu

DIG IN Menu
Parameter
Choices
Level 2 submenus
DIGIN1
OFF
DIGIN2
ZERO
DIGIN3
NT/GRS
TARE
UNITS
PRINT
ACCUM
DSPTAR
ENTER
KBDLOC
HOLD
BATRUN
BATSTRT
BATPAUS
CLRCN
GROSS
NET
PRIM
SEC
CLRTAR
CLRACC
38
520 Installation Manual
Figure 3-16. Digital Input Menu
Specifies the function activated by digital inputs 1–3. Default values are: DIGIN1=BATSTRT;
DIGIN2=BATRUN; DIGIN3=OFF.
• ZERO, NT/GRS (net/gross mode toggle), TARE, UNITS, and PRINT provide the same
functions as the five front panel keys.
• ACCUM displays the current accumulator value.
• DSPTAR displays the tare.
• ENTER simulates pressing the ENTER key in weigh mode (for setpoint and checkweigh
value changes from the front panel).
• BATRUN allows a batch routine to be started and run. With BATRUN active (low), the
BATSTRT input starts the batch; if BATRUN is inactive (high), BATSTRT cancels the batch.
• BATSTRT starts or ends a batch routine, depending on the state of the BATRUN input.
• BATPAUS pauses a batch routine when held low.
• KBDLOC locks the keyboard (indicator front panel) when held low.
• HOLD holds the current display. Releasing this input clears the running average filter.
• CLRCN resets the consecutive number to the value specified on the CONSTUP parameter
(PROGRM menu).
• GROSS, NET, PRIM, and SEC select gross, net, primary units, or secondary units display
modes.
• CLRTAR clears the current tare.
• CLRACC clears the accumulator.
Table 3-8. Digital Input Menu Parameters