Table 3-6 Typical Power Loads And Heat Dissipation Values - Mts 800 Mhz Configuration - Motorola DIMETRA MTS 2 Installation, Configuration And Basic Service Manual

Hide thumbs Also See for DIMETRA MTS 2:
Table of Contents

Advertisement

Service Current Rating
Table 3-5 Typical Power Loads and Heat Dissipation Values - Expansion Cabinet UHF
Configuration (Continued)
Expansion
Cabinet
Consumptions
MTS UHF
Configuration
MTS4 Exp. Cab.
w. 4 BRs w.
MTCC/ATCC
TETRA TX 25 W and TEDS TX 10 W
MTS4 Exp. Cab.
w. 1 BR w.
MTCC/ATCC
MTS4 Exp. Cab.
w. 2 BRs w.
MTCC/ATCC
MTS4 Exp. Cab.
w. 3 BRs w.
MTCC/ATCC
MTS4 Exp. Cab.
w. 4 BRs w.
MTCC/ATCC
Table 3-6 Typical Power Loads and Heat Dissipation Values - MTS 800 MHz Configuration
MTS 800 MHz
Configuration
TETRA TX 10 W
MTS2 with 1 BR
MTS2 with 1 BR w.
Hybrid
MTS2 with 2 BRs
MTS2 with 2 BRs w.
Hybrid
MTS4 with 1 BR w.
MTCC
MTS4 with 2 BRs w.
MTCC
MTS4 with 3 BRs w.
MTCC
3-18
AC
Heat
When
AC
AC
Charg-
(W)
(W)
ing (W)
760
720
2005
370
345
750
630
580
1010
1025
950
1785
1300
1200
2065
AC
Heat
When
AC
AC
Charg-
(W)
(W)
ing (W)
280
270
660
320
310
705
445
425
825
530
510
915
320
310
705
530
510
915
855
825
1620
Heat AC
When
DC
Heat
Charging
-48 V
DC
(W)
(W)
(W)
835
745
705
420
365
340
670
615
565
1110
1000
925
1375
1270
1170
Heat AC
When
DC
Heat
Charging
-48 V
DC
(W)
(W)
(W)
325
215
205
370
235
225
480
315
295
570
365
345
370
235
225
570
365
345
940
605
575
Chapter 3: Site Preparation
Comment
Low power PA,
fans
High power PA,
fans
High power PA,
fans
High power PA,
fans
High power PA,
fans
Comment
No combining,
high power PA,
fans
High power PA,
fans
Two TX ant., low
power PA, fans
High power PA,
fans
High power PA,
fans
High power PA,
fans
High power PA,
fans
6802800U74-N September 2009

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dimetra mts 4