MTS - Configuring Ethernet Site Link
Procedure 8-12 MTS - How to Configure E1 Links (Continued)
6
7
8
9
10
MTS - Configuring Ethernet Site Link
In order to setup Ethernet Site Link, the following parameters must be configured for Base Station:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
8-30
For up to 10 MTSs connected in the line topology (i.e. Core Router 1 -----MTS1-----MTS2---....-
----MTS10(last)) use the following commands on all MTSs execpt for the last one:
.e1config -siteLink single
.e1config -DI on
.e1config -channel 1 -portNo 1
.e1config -channel 2 -portNo 2
.e1config -channel 1 -tsPattern X1 X2 ...
.e1config -channel 2 -tsPattern Y1 Y2 ...
Timeslots configured for each site in the line must be different.
Configure the last MTS in the chain as follows:
.e1config -siteLink single
.e1config -DI off
.e1config -channel 1 -portNo 1
.e1config -channel 1 -tsPattern X1 X2 ...
If the 16th timeslot on the E1 link should be allocated for signalling/synchronization according
to service provider specification, type .e1config -ts16skip on.
Type .e1config to verify that the new E1 configuration appears correctly below Next.
Type reset to reset the Site Controller and press Enter.
Type .e1config to verify that the new configuration has been set to Current.
Primary WAN Interface IP Address
Primary WAN Interface IP Netmask
Primary WAN Interface Gateway
Primary WAN Interface VLAN ID
Primary WAN Interface VLAN tagging
Primary IP Tunnel Remote IP Address
Primary IP Tunnel Fragmentation Size
Green Color Map - Yellow Color Map
CIR
CBS
EIR
EBS
Primary PVC IP Address
Primary PVC Network Mask
Secondary PVC IP address
Secondary PVC Network Mask
Chapter 8: Site Controller
6802800U74-N September 2009