Base Radio - Indicators and Connectors
Base Radio - Indicators and Connectors
■
■
■
■
■
■
■
■
■
■
■
■
■
Table 10-1 Base Radio - LED Indicators
#
LED 1
LED 2
LED 3
LED 4
LED5
LED6
LED7
LED8
10-8
■
■
■
■
■
■
■
■
■
■
■
■
■
LED/Port name
Type
Tx
Red/Green
Aux
Red/Green
Status
Red/Green
BR Alarm
Red/Green
SC 1
Green
SC 1
Yellow
SC 2
Green
SC 2
Yellow
■
■
■
■
■
■
■
■
■
■
■
■
■
■
Controlled by
SW
SW
SW Red LED will
turn on before
SW change any
indication
SW
HW, Enet IC
HW, Enet IC
HW, Enet IC
HW, Enet IC
■
■
■
■
■
■
Indication
BR keying:
• OFF: BR is not keyed
• AMBER: BR is keyed without
service
• GREEN: BR is keyed
• OFF: No alarms
• AMBER: not used
• RED: not used
BR status:
• OFF: Status unknown, power off
• GREEN: BRC main application
is running
• AMBER: Waiting for SWDL –
this is where the BR will wait if
no Site Controller is present
• RED: SW not started, power on
OFF: No alarms
•
• AMBER: BR minor alarm: PA,
Exciter, RX, BRC Reduced
performance
• RED: BR failed: PA, Exciter,
RX, BRC
• OFF: Ethernet link not present
GREEN: Ethernet link present
•
• OFF: Ethernet activity not present
• YELLOW: Ethernet activity
present
OFF: Ethernet link not present
•
GREEN: Ethernet link present
•
• OFF: Ethernet activity not present
• YELLOW: Ethernet activity
present
6802800U74-N September 2009