Motorola DIMETRA MTS 2 Installation, Configuration And Basic Service Manual page 382

Hide thumbs Also See for DIMETRA MTS 2:
Table of Contents

Advertisement

Site Link
Datagrams supplied by IP user-protocols
Outbound datagrams discarded
IP datagrams dropped due to no routes
If there are issues with configuration for CRTP "header extensions", this will be indicated by the
counter labeled "UDP datagrams received for unknown ports or with other errors".
Site Link
Troubleshooting the Site Link essentially consists of checking the correct operation of each
layer in the order starting with the physical layer.
The physical layer may be configured to be either E1 or X.21. The status bsl command
provides different information for the two interface types.
X.21 Interface
If the Site Link interface had been configured to use X.21 interface, the information
provided by the status bsl command is as follows:
SC) status bsl
Primary Site Link –
State:DOWN
HDLC Statistics:-
Good frames
Overruns | Underruns
C Line | I Line lost
CRC/framing errors
No buffers avail
Buffer overflows
Aborts
Non octet aligned
X.21 Interface:-
Clock Loss events
I Line Off events
Current Clock state
Current I Line state
Current C Line state
13-16
Speed:
----Rx----
: 0
: 0
: 0
: 0
: 0
: 0
: 0
: 0
: 2
: 0
: Failed
: On
: Off
The Site Link State should be shown as 'UP', the number of good frames transmitted and
received should be non-zero and incrementing indicating site link traffic. The presence of
non-zero data in other numeric fields may indicate a possible Site Link Problem.
0 bps
Chapter 13: MTS Troubleshooting
14369
0
0
Rear port:X.21
----Tx----
0
0
0
6802800U74-N September 2009

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dimetra mts 4

Table of Contents