MTS 2 and MTS 4 Installation, Configuration and Basic Service Manual
Procedure 8-28 How to Configure Ethernet Ports (Continued)
6
7
Procedure 8-29 How to Configure SC IDs
1
2
3
4
5
6
7
6802800U74-N September 2009
From the prompt, run the command spw inet/if/eth1 "dhcp:no
addr:10.0.(255–X).X mask:255.255.255.0 dev_name:tsec1 dev_unit:1
ethaddr:
yy:yy:yy:yy:yy:yy mtu:1500"
Remember to check the IP settings on both SCs.
For an MTS using a single Site Controller, the Ethernet settings should be checked
using the ifconfig -a command from the SC application prompt. From the
output, confirm that the eth0 and eth1 ports are configured as expected. See Procedure
below for more information on how to set SC IDs.
The SCs must have different ID values configured. To check the SC id, follow the steps below.
Log onto the Site Controller Application MMI.
From the SC: prompt, run the command id.
An id value of either A or B is displayed.
Perform the same check on the second Site Controller.
If the IDs are the same, one of the ID values have to be changed. To do so, log onto the Site
Controller Application MMI.
It does not matter if it is the ID value of SC1 or SC2 that is changed, as long as they
do not have the same ID value.
From the SC: prompt, run the command id x where x can be either A or B. Make sure to define
a value different for the two SCs.
Reset the Site Controller.
• There is one space between the ethaddr: and the
yy:yy:yy:yy:yy:yy in the command above.
• X = 1 for SC1, and 2 for SC2
• yy:yy:yy:yy:yy:yy = the MAC address of the interface. Note that
eth0 and eth1 have different MAC addresses.
Configuring Redundant Site Controller
8-49