Motorola DIMETRA MTS 2 Installation, Configuration And Basic Service Manual page 323

Hide thumbs Also See for DIMETRA MTS 2:
Table of Contents

Advertisement

MTS 2 and MTS 4 Installation, Configuration and Basic Service Manual
Process 8-7 How to Configure Redundant Site Controllers
1
2
3
4
Procedure 8-26 Site Controller Hardware Pre-Checks
1
2
3
4
Procedure 8-27 Site Controller Configuration Files
1
2
3
4
5
6
7
8
6802800U74-N September 2009
Perform Site Controller Hardware Pre-Checks, as described in
Hardware Pre-Checks," on page
Configure the Site Controller Configuration Files, see
Configuration Files," on page
Configure Ethernet ports connecting the two Site Controllers, as described in
"How to Configure Ethernet Ports," on page
Configure the ID values of the Site Controllers, see
IDs," on page
8-49.
Ensure that both SCs are correctly installed and are running identical software applications,
Boot images and configuration files.
In order for the Redundant Site Controller feature to work correctly, the Site Controller and
BR Boot1 version must be:
• TSC_RLJ_BOOT1–R06.40.07 or later for Site Controller.
• BRC_RLJ_BOOT1–R06.40.05 or later for Base Radio.
The Boot1 version can be checked on the Site Controller and BRs by using the ver
command on both the Site Controller and on the Base Radio.
Check that the redundant Site Controller Ethernet Link cables are connected correctly, as shown
in Figure 5–6.
Proceed to
Procedure 8-27
In order to check that the Site Controller configuration files have the Standby Site
Controller Installed parameter enabled, follow the steps below.
Log onto the Site Controller Application MMI.
From the SC: prompt, run the command display config.
Check the output of the configuration and confirm if the Standby SC parameter is enabled or not.
If no Standby Site Controller is enabled, upload the Active Site Controller configuration file.
Modify the configuration file in TESS to enable Standby Site Controller.
Download the new configuration file to the InActive Bank (set to use as next after reset).
Reset the Site Controller.
Confirm the configuration is correct.
8-47.
8-47.
8-48.
Procedure 8-29, "How to Configure SC
below.
Configuring Redundant Site Controller
Procedure 8-26, "Site Controller
Procedure 8-27, "Site Controller
Procedure 8-28,
8-47