Upgrading Test Application - Motorola DIMETRA MTS 2 Installation, Configuration And Basic Service Manual

Hide thumbs Also See for DIMETRA MTS 2:
Table of Contents

Advertisement

MTS 2 and MTS 4 Installation, Configuration and Basic Service Manual

Upgrading Test Application

Perform
Procedure 8-30
Procedure 8-30 How to Upgrade the Site Controller Test Application
1
2
3
4
5
6
7
6802800U74-N September 2009
in order to upgrade the Test Application.
Open 3 COM server application and configure it to point to the folder containing the Test
Application software.
Connect a RJ45 cable to the serial port on the PC and to the Service port on the Site Controller.
Connect a crossover Ethernet cable to the PC and to the Red In port on the Site Controller.
Reset the Site Controller and enter boot1 mode.
Type ferase 0xff780000 4M and press Enter.
When prompt returns type finstall TA /tftp/10.0.253.100/R064009ROM.hex
and press Enter.
The R064009ROM.hex stated in the command above is used just as an example. If
newer version exist, use this when executing the command.
When the file transfer has finished and the prompt appears reset the Site Controller.