MTS - Configuring Cooling Fans
MTS - Configuring Cooling Fans
Procedure 8-14 MTS - How to Configure the Cooling Fans
1
2
3
4
5
MTS - Loading Ki's Into MTS
Process 8-4 MTS - Loading Ki's Into MTS
Refresh Ki's. See
1
Connect KVL to the AuC. See
2
Download Ki's from AuC to KVL. Use local or remote connection. See:
3
Check the Inventory in KVL. See
4
Download Ki's from KVL to Site Controller/BRC. See
5
the Site Controller/BRC" on page
Upload site receipts (locally or remotely). See
6
8-34
Procedure 8-14
needs to be repeated each time a Site Controller has been replaced.
Make sure you are logged on to the Site Controller.
To get the current fan configuration, type psu 1 get fan_config and press Enter.
If applicable, repeat for PSU 2.
To set new fan configuration, use the psu # set fan_config command.
Examples:
psu 1 set fan_config 1 1 1 to define three fans present on PSU 1.
psu 2 set fan_config 0 0 0 to define no fans present on PSU 2.
If a redundant Site Controller is available in the system, repeat
Controller while it is active.
Return to
Process 8-1, "MTS – Replacing Site Controller," on page
"MTS - Refreshing Ki's for the MTS" on page
"MTS - Downloading Ki's from the AuC to KVL (Locally)" on page
"MTS - Downloading Ki's from the AuC to KVL (Remotely Using GSM)" on page
"MTS - Uploading the Site Receipts (Locally)" on page 8-38
"MTS - Uploading the Site Receipts (Remotely using GSM)" on page 8-38
"MTS - Connecting KVL to the AuC" on page
"MTS - Checking the Inventory in
"MTS - Downloading Ki's from KVL to
8-37.
Chapter 8: Site Controller
step 3
on the second Site
8-19.
8-35.
8-35.
8-36.
8-36.
KVL".