Fuse Setting - R&S NGE100B User Manual

Hide thumbs Also See for NGE100B:
Table of Contents

Advertisement

®
R&S
NGE100B
OUTPut:SELect <arg0>
This command activates or queries the instrument channel state of the previous
selected channel.
If the selected channel is activated, the respective channel key (i.e. Ch 1, Ch 2, Ch 3)
on the front panel will be illuminated.
Parameters:
<arg0>
Example:
OUTP:SEL? -> 1
Return the state of the selected channel.
OTP:TRIPped?
Queries the overtemperature protection (OTP) tripped state of the previous selected
channel.
It is tripped if an OTP event occurs. Available from V1.50
Return values:
<arg0>
Example:
Usage:

7.3.6 Fuse setting

The FUSE subsystem contains the commands for overcurrent protection parameters
such as activating fuses and setting fuse parameters of the output channels. The
default unit is A.
User Manual 5601.1343.02 ─ 09
{OFF | ON | 0 | 1}
ON | 1
Selected channel will be activated.
OFF | 0
Selected channel will be deactivated.
*RST:
OFF | 0
INST OUT1
OUTP:SEL ON
Ch 1 is activated.
{OFF | ON | 0 | 1}
ON | 1
OTP event occurs.
OFF | 0
OTP event not occurs.
*RST:
OFF | 0
OUTP:TRIP? -> 1
OTP event occurs.
Query only
Remote control commands
Configuration commands
83

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nge102bNge103b