R&S NGE100B User Manual page 100

Hide thumbs Also See for NGE100B:
Table of Contents

Advertisement

®
R&S
NGE100B
TRIGger:OUT:CRITevent:DIO<IO> <arg0>
This command sets or queries the critical event of the trigger output of the specified
Digital I/O line.
Suffix:
<IO>
Parameters:
<arg0>
TRIGger:OUT:CURRlevel:DIO<IO> <Current>
This command sets or queries the threshold current level of the trigger output of the
specified Digital I/O line.
Triggers when output current level exceeds or equals to the set level.
Suffix:
<IO>
Parameters:
<Current>
User Manual 5601.1343.02 ─ 09
ON
Trigger output is turned on.
OFF
Trigger output is turned off.
FUSetrip
Trigger output is linked to fuse tripped event.
VOLTlevel
Trigger output is linked to a set voltage level event.
CURRlevel
Trigger output is linked to a set current level event.
CRITevent
Trigger output is linked to a critical triggered event.
ARBitrary
Trigger output is linked to a EasyArb event.
*RST:
ON
.
1..4
OVP | OPP | OTP
OVP
Trigger output is linked to the OVP event.
OPP
Trigger output is linked to the OPP event.
OTP
Trigger output is linked to the OTP event.
*RST:
OVP
.
1..4
*RST:
3.000
Default unit: A