R&S
NGE100B
Figure 5-8: Output performance graph
According to the basic electrical formula for power (P) = current (I) x voltage (V), the
following results for the maximum power per channel:
●
NGE102B: 33.6 W per channel (67 W max for the combination of two channels)
●
NGE103B: 33.6 W per channel (100 W max for the combination of three channels)
For more information on the combination of channels, see
series
5.5 Operation modes
The R&S NGE100B operates in two different modes, i.e. CV and CC. The instrument
switches automatically between CV and CC depending on the connected load.
CV mode
Figure 5-9
voltage V
when the connected load is increasing. In CV mode, the font text in the channel display
area changes to green.
See
User Manual 5601.1343.02 ─ 09
mode",
on page 105.
shows that if the instrument is in the range of voltage regulation, the output
remains constant while the current may increase to its maximum value I
out
Figure
5-3.
Operating basics
Operation modes
Chapter 9.1, "Parallel and
max
37