10 TOOLS
PRODUCTION STATISTICS
ARCTIME
CONSUMED WIRE
BASED ON
NUMBER OF WELDS
CONSUMED ICE WIRE
DEPOSITION RATE
LAST RESET
RESET
When you press RESET, all counters are reset. Date and time show the most recent reset.
If you do not reset the counters, these are all automatically reset when one of them has
reached its maximum value.
Maximum counter values
Time
999 hours, 59 minutes, 59 seconds
Weight
13350000 grams
Quantity
65535
10.7

Quality functions

MAIN MENU » TOOLS » QUALITY FUNCTIONS
Quality functions keep track of various interesting weld data for individual welds.
These functions are:
Time of welding start.
Duration of welding.
Maximum, minimum and average current during welding.
Maximum, minimum and average voltage during welding.
Maximum, minimum and average energy per unit length during welding.
The number of welds since the most recent reset is displayed in the row at the bottom.
Information can be stored about a maximum of 100 welds. In the event of more than 100
welds, the first one is overwritten.
The most recently noted weld is presented in the display, although it is also possible to
browse between other noted welds. All logs are deleted when you press RESET.
QUALITY FUNCTIONS
#WELD: 1 / 4
START 20190807 15:59:14
WELD TIME 00:00:20 WELD DATA:
HEAT INPUT: 3.12 kJ/min
0460 949 474
UPDATE
- 68 -
LAST WELD
0s
0g
1g/m
 
 
0 kg/h
081114
TOTAL
0s
0g
 
0
 
0 kg/h
08:38:03
QUIT