Quality Functions - ESAB PEK A2 Instruction Manual

Hide thumbs Also See for PEK A2:
Table of Contents

Advertisement

GB
When you press RESET, all counters are reset. Date and time show the most recent
reset.
If you do not reset the counters, these are all automatically reset when one of them
has reached its maximum value.
Maximum counter values
Time
999 hours, 59 minutes, 59 seconds
Weight
13350000 grams
Quantity
65535
9.7

Quality functions

Main menu ³ Tools ³ Quality functions
Quality functions keep track of various interesting weld data for individual welds.
These functions are:
S
Time of welding start.
Duration of welding.
S
Maximum, minimum and average current during welding.
S
Maximum, minimum and average voltage during welding.
S
Maximum, minimum and average energy per unit length during welding.
S
The number of welds since the most recent reset is displayed in the row at the
bottom. Information can be stored about a maximum of 100 welds. In the event of
more than 100 welds, the first one is overwritten.
The most recently noted weld is presented in the display, although it is also possible
to browse between other noted welds. All logs are deleted when you press RESET.
bi24d1ea
QUALITY FUNCTIONS
#WELD: 1 / 4
START 20090107 15:59:14
WELD TIME 00:00:20 WELD DATA:
HEAT INPUT: 3.12 kJ/mm
MAX
I (Amp)
293.00
U (V)
41.50
Q (kJ/min)
7.00
NUMBER OF WELDS SINCE RESET: 4
RESET
UPDATE
− 50 −
MIN
AVE.
243.00
289.00
16.20
39.40
0.00
2.00
QUIT