8 MEMORY MANAGEMENT

8
MEMORY MANAGEMENT
8.1

Control panel working method

The control panel can be said to comprise two units: working memory and weld data
memory.
Working Memory
In the working memory, a complete set of weld data settings is created that can be stored in
the weld data memory.
During welding, it is always the content of the working memory that controls the process. It is
therefore also possible to recall a weld data set from the weld data memory to the working
memory.
Note that the working memory always contains the most recently set weld data settings.
They can be recalled from the weld data memory or individually altered settings. In other
words, the working memory is never empty or "zeroed".
MAIN MENU » MEMORY » WELD DATA MEMORY
WELD DATA MEMORY
 
 
 

STORE

It is possible to store up to 255 sets of weld data in the control panel. Each set is given a
number from 1 to 255.
You can also delete, copy, change and name data sets and recall a set of weld data to the
working memory.
8.2
Store
If the weld data memory is empty, the following screen appears in the display.
Storing a set of weld data. This will be given memory position 5. Press STORE.
Position 1 is displayed. Turn one of the settings knobs until you reach position 5. Press
STORE.
WELD DATA MEMORY
  
  
 
STORE
The following screen appears in the display.
The weld data set is now stored as number 5.
0460 949 474
Store
Recall
2ND FUNCT
2ND FUNCT
- 33 -
Welding data memory
QUIT
QUIT