9 CONFIGURATION MENU
1.
HEAD, Welding head 1 (master)
2.
TAIL, welding head 2 (slave)
PHASE SHIFT (applies only to AC welding)
Phase shift means a phase offset in relation to the front welding head. The unit is degrees.
9.3.8
Parallel power sources (applies only to Aristo® 1000 power sources)
To be able to set up two power sources in parallel, only the two power sources that are to be
connected should have power on and be active on the CAN2 bus.
PARALLEL POWERSOURCES
PARALLEL POWERSOURCES
Parallel couple ID
Connect with slave
 
Perform settings for parallel power sources as follows:
1.
Set the PARALLEL POWERSOURCES function to ON.
2.
Set Parallel couple ID. The first parallel couple is set to 1, the next parallel couple is
set to 2 etc.
3.
Select menu line Connect with slave and press ENTER.
A message Connect appears.
4.
Press ENTER again.
0460 949 474
3.
WELD HEAD OFFSET
- 52 -
OFF
1
- -
QUIT