2 MENUS
cm/min - Measured ICE wire feed speed
kg/h - Indicates used material per / hour
The measured values remain in the display even after welding has been completed.
You can move to different menus without losing the measurement values.
The settings knobs can be used to change the welding parameters in the measurement
display.
If the set value is changed when welding is not in progress, the measurement value changes
to zero.
For activating ICE wire feed, a soft key, ICE WF, is activated, see section "Soft key
configuration". When the key is depressed, the ICE wire speed is changed using the left
settings knob A. If the soft key is not depressed, the settings knob affects the A current.
In the measurement display one can also see the set values if the soft key SET VALUES is
activated. If both soft keys, ICE WF and SET VALUES are activated, the set feed speed for
cold wire can be changed. For activating see section "Soft key configuration".
SAW: CW
NONE
DIR: SQUARE
300 cm/min - Set wire feed speed
20.0 Volt - Set arc voltage
30 cm/min - Set travel speed
2.1.5

Weld data memory menu

MAIN MENU » MEMORY
In the WELD DATA MEMORY menu you can store, recall, delete and copy various set weld
data. The weld data sets can be stored in 255 different memory positions.
WELD DATA MEMORY
1 (SAW)
7 (GMAW)
  
 
STORE
For further information, see section "MEMORY MANAGEMENT".
2.1.6

Fast mode menu

MAIN MENU » FAST MODE
0460 949 474
NONE
SET VALUES
2ND FUNCT
- 15 -
2ND FUNCT
QUIT
© ESAB AB 2021