10 TOOLS
QUALITY FUNCTIONS
 
I (Amp)
U (V)
Q (kJ/min)
V(t) (cm/min)
V(w) (cm/min)
NUMBER OF WELDS SINCE RESET: 4
RESET
10.7.1

Store quality data

MAIN MENU » TOOLS » EXPORT / IMPORT
The files that are produced in the control panel are stored as xml files. The USB memory
must be formatted as FAT32 in order to work.
Insert a USB memory in the control panel, see section "File manager".
Select QUALITY FUNCTION LOG, press EXPORT.
EXPORT/IMPORT
WELD DATA SETS
SYSTEM SETTINGS
SETTING LIMITS
MEASURE LIMITS
ERROR LOG
QUALITY FUNCTION LOG
PRODUCTION STATISTICS
EXPORT
The entire set of quality data (information about the 100 most recent welds) that is stored in
the control panel is now saved on the USB memory.
The file is in a folder called QData. QData is created automatically when you insert a USB
memory.
10.7.2

Import system settings

When changing between Aristo® 1000 and LAF/TAF power sources use SYSTEM
SETTINGS to import system settings.
When EXPORT/IMPORT is selected you can import settings by marking the SYSTEM
SETTINGS using the positioning knob and pressing IMPORT.
0460 949 474
MAX
293.00
41.50
7.00
0.00
0.00
UPDATE
- 69 -
MIN
AVE.
243.00
289.00
16.20
39.40
0.00
2.00
0.00
0.00
0.00
0.00
QUIT
QUIT
© ESAB AB 2021