Hidden Tig Functions; Mma Welding; Settings - ESAB Origo TA23 Instruction Manual

Table of Contents

Advertisement

GB
2.3

Hidden TIG functions

There are hidden functions in the control panel.
To access the functions, press
a value. Select function by pressing the right arrow. The knob is used to change the
value of the selected function.
To access hidden functions, press
Control panel TA23
Function
A = gas pre-flow
I = min current
Gas pre-flow
This controls the time during which shielding gas flows before the arc is struck.
Min current
Used to set the minimum current for the remote control T1 Foot CAN.
If the max current is 100 A and the min current is to be 50 A, set the hidden function
min current to 50%.
If the max current is 100 A and the min current is to be 90 A, set the min current to
90%.
3

MMA WELDING

3.1

Settings

Function
Current
2)
Hotstart
2)
Arc force
2)
Drop welding
2)
Weld regulator
Active panel
Remote control unit
VRD
1)
The setting range is dependent on the power source used.
2)
These functions are hidden functions, see description point 3.3.
bi15d1ea
for 5 seconds. The display shows a letter and
for 5 seconds.
Settings
0 - 5 s
0 - 99%
Setting range
1)
16 A -max
0 - 99
0 - 99
0=OFF or 1=ON
1=ArcPlust II or 0=ArcPlust
OFF or ON
OFF or ON
-
- 7 -

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents