9 CONFIGURATION MENU
External axis
To be activated when there is an external I/O unit for controlling a roller bed, for
example.
Tandem
Used when welding with two welding heads.
Cold wire (ICE)
Used when a non-live wire is fed into the weld pool and the cold wire speed is to be
shown in the display.
Auto step
Used in the step function
○ Auto step Off: Setting during preparation of the object before welding
○ Auto step On: Setting after preparation is finished when welding should be
executed
Force step
Used in the step function to manually force one auto step during welding
Restart step
When welding is stopped with 100mm left to the start of the next step. Press restart
step and the next step is after 100mm, not after Xmm. Then press the welding start key.
Stop zero
Used to stop automatically at the started rotation position.
In the display screen there are two columns; one for SOFT KEYS and one for FUNCTION.
SOFT KEYS SETUP
SOFT KEYS
S1
S2
S3
S4
S1 2ND FUNCT
S2 2ND FUNCT
S3 2ND FUNCT
S4 2ND FUNCT
When you allocate functions to these keys, they are numbered from the left as follows:
S1
S1 2ND FUNCT
S2 2ND FUNCT
To allocate a new function to a soft key, proceed as follows:
Position the cursor on the row with the soft key number you wish to use and press ENTER. A
pop-up menu shows the function selections. Select using the positioning knob and press
ENTER.
0460 949 474
S2
S3
S3 2ND FUNCT S4 SND FUNCT
- 42 -
FUNCTION
QUIT
S4
2ND FUNCT
2ND FUNCT
© ESAB AB 2021
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE

Hide quick links: