10 TOOLS
10.4

Setting limit editor

MAIN MENU » TOOLS » SETTING LIMIT EDITOR
In this menu you set your own max. and min. values for various welding methods. The limits
cannot be above or below the values for which the power source is dimensioned. There are
50 storage points. Select the row for an empty storage point and press ENTER. Select
process by pressing ENTER and select the welding process using the positioning knob and
press ENTER.
The maximum and minimum values for arc voltage, wire feed speed, travel speed and
welding current can be selected for all processes.
EDIT LIMITS
PROCESS
VOLTAGE
VOLTAGE
WIRE SPEED
WIRE SPEED
TRAVEL SPEED
TRAVEL SPEED
CURRENT
CURRENT
STORE
LIMITS
  1 SAW
  2 GMAW
  3 GOUGING
  4 -
  5 -
  6 -
  7 -
When the values have been adjusted, press STORE. When asked if the limit value is to be
saved at the selected storage point, press NO or YES. The storage point's values can be
seen under the line at the bottom.
With the AUTO soft key, the parameters are set automatically according to the most recently
used parameters.
When asked if the limit settings are to be set automatically, press NO or YES and then
STORE if the setting is to be retained.
0460 949 474
DELETE
17.0 - 47.0 Volt , 50 - 970 cm/min
100 - 2400 cm/min , 70 - 1500 Amp
- 66 -
SAW
MIN 17.0
MAX 47.0
MIN 50
MAX 970
MIN 100
MAX 2400
MIN 70
MAX 1500
QUIT
QUIT