Auto Save Mode; Machine Configuration - ESAB A2 PEK Instruction Manual

Hide thumbs Also See for A2 PEK:
Table of Contents

Advertisement

9 CONFIGURATION MENU
SOFT KEY SETUP
SOFT KEYS
S1
S2
S3
S4
S1 2ND FUNCT
S2 2ND FUNCT
S3 2ND FUNCT
S4 2ND FUNCT
NONE
GAS / FLUX
SET VALUES
RELAY 1
DIRECTION
REMOTE IO
EXT. AXIS
AUTO STEP
FORCE STEP
RESTART STEP
STOP ZERO
You can allocate new functions to the other keys in the same way, by pairing a key number in
the left-hand column with a function in the right-hand column.
9.2.4

Auto save mode

When a weld data set has been recalled from a memory position in the weld data memory
and you change the settings, the changes will be saved in the working memory at welding
stop in the last recalled memory position.
Saving weld data manually in a memory position disables the next automatic save.
The memory position in which the weld data set is stored is displayed in the top right corner
of the measure screen.
9.3

Machine configuration

MAIN MENU » CONFIGURATION » MACHINE CONFIGURATION
In this menu you can set:
Product code, see section "Product code".
Wire feed axis, see section "Wire feed axis".
Cold wire feed axis, see section "Cold wire axis (ICE)".
Travel axis, see section "Travel axis".
External axis, see section "External axis".
0460 949 474
- 43 -
FUNCTION
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
QUIT
© ESAB AB 2021