Remote control unit
Settings are made from the remote control unit.
The remote control unit must be connected to the remote control unit socket on the
machine before activation. When the remote control unit is activated the panel is
inactive.
2.3

Hidden TIG functions

There are hidden functions in the control panel.
To access the functions, press
a value. Select function by pressing the right arrow. The knob is used to change the
value of the selected function.
To leave hidden functions, press
Control panel TA33
Function
A = gas pre--flow
b = slope up
C = metric/inch
Control panel TA34
Function
A = gas pre--flow
b = micro pulse
I = min current
Gas pre- - flow
This controls the time during which shielding gas flows before the arc is struck.
Micro pulse
In order to select micro pulse, the machine must be in the pulsed current function
. The value for pulse time and background current is normally 0.01 – 2.50
seconds. By using the micro pulse, the time can go down to 0.001 seconds. When
the micro pulse function is active, times that are shorter than 0.25 seconds are
shown in the display without decimal points.
Min current
Used to set the minimum current for the remote control T1 Foot CAN.
If the max current is 100 A and the min current is to be 50 A, set the concealed
function min current to 50%.
If the max current is 100 A and the min current is to be 90 A, set the min current to
90%.
bi19d2ea
for 5 seconds. The display shows a letter and
for 5 seconds.
0 = inch, 1 = mm
0 = OFF; 1 = ON
- - 23 - -
Settings
0 -- 5 s
0 -- 9,9
Settings
0 -- 5 s
0 -- 99%