10 TOOLS
10.5

Measure limits editor

MAIN MENU » TOOLS » MEASURE LIMITS EDITOR
In this menu you set your own measurement values for the various welding methods. There
are 50 storage points. Select the row for an empty storage point and press ENTER. Select
PROCESS by pressing ENTER and select the welding process using the positioning knob
and press ENTER.
The following values can be selected:
arc voltage: min, max
wire feed speed: min, max
welding current: min, max
travel speed: min, max
energy per unit length: min, max
Set the desired value using the setting knobs and press STORE.
In the dialogue box, you are asked if you want to store the selected storage point. Press YES
to save the value. The storage point's values can be seen under the line at the bottom.
MEASURE LIMITS
1 SAW
2 GMAW
3 -
4 -
5 -
6 -
7 -
With the AUTO soft key, the parameters are set automatically according to the most recently
used measurement values.
When asked if the measurement values are to be set automatically, press NO or YES and
then STORE if the setting is to be retained.
10.6

Production statistics

MAIN MENU » TOOLS » PRODUCTION STATISTICS
The production statistics will keep track of the total arc time, the total amount of material and
the number of welds since the most recent reset. They will also keep track of the arc time
and the amount of material used in the most recent weld. For information purposes, the
melted wire material per length unit that has been calculated and when the most recent reset
occurred are also displayed.
0460 949 474
0.0 - 46.9 Volt , 0 - 2495 cm/min
3 - 994 cm/min , 3 - 990 Amp
5 - 500 kJ/min
- 67 -