3 SUBMERGED ARC WELDING
Settings
3)
AC balance
3)
AC offset
2)
Start data
Flux pre-flow
Start adjust
Start type
Wire creep start
Wire creep start speed
Start phases
Open-circuit voltage
Maximum open-circuit voltage
2)
Stop data
Flux post-flow
Crater filling
Crater filling time
Burnback time
Stop phases
Control parameters
Dynamics
Inductance
Setting limits
Measure limits
1)
The setting range is dependent on the product used.
2)
The menu shows the settings that belong to the selected regulation type.
3)
Applies only to Aristo® 1000 power sources
0460 949 474
Setting range
In steps of
25 - 75%
1
-300-+ A/-10 +10V 1 A / 0.1 V
0 - 99.0 s
0.1 s
Min = 50%
1%
Direct or Scratch
-
Auto or Set speed -
0 - 1000 cm/min
1 cm/min
OFF or ON
-
OFF or ON
-
5 - 60 V
0.1 V
0 - 99.0 s
0.1 s
OFF or ON
-
0 - 10 s
0.01 s
0- 10 s
0.01 s
OFF or ON
-
Auto or Set values -
Auto or Set values -
-
-
-
-
- 18 -
Value after
resetting
50%
0
0 s
100%
Direct
Auto
20 cm/min
OFF
OFF
50 V
0 s
OFF
0.0 s
0.65 s
OFF
Auto
Auto
-
-