Origo™
TA23
Instruction manual
0460 032 174 GB 100702
Valid from program version 1.01

Advertisement

Table of Contents
loading

Summary of Contents for ESAB Origo TA23

  • Page 1 Origo™ TA23 Instruction manual 0460 032 174 GB 100702 Valid from program version 1.01...
  • Page 2: Table Of Contents

    1 INTRODUCTION ........... 1.1 Control panel TA23 .
  • Page 3: Introduction

    INTRODUCTION The manual describes the use of TA23 control panel. For general information about operation see user's instructions for the power source. When mains power is supplied the unit runs a self diagnosis of the LEDs and the display, the program version is displayed and in this example the program version is 0.18A Control panel TA23 Knob for setting current (A) or time (s)
  • Page 4: Tig Welding

    TIG WELDING Settings TIG without pulsing Function Setting range HF / LiftArc t HF or LiftArct 2/4-stroke 2 stroke or 4 stroke Gas pre flow time 0 -5 s Slope up-time 0 -10 s Slope down time 0 -10 s Gas post flow time 0 -25 s Current...
  • Page 5 Slope down TIG welding uses “slope down”, by which the current falls 'slowly' over a controlled time, to avoid craters and/or cracks. when a weld is finished. Gas post-flow This controls the time during which shielding gas flows after the arc is extinguished. The HF function strikes the arc by means of a spark from the electrode to the workpiece as the electrode is brought closer to the workpiece.
  • Page 6 If the VRD function is activated and the open-circuit voltage exceeds the 35 V limit, this is indicated by an error message (16) appearing in the display and welding cannot be started whilst the error message is displayed. Contact an authorised ESAB service technician to activate the function. - 6 - bi15d1ea...
  • Page 7: Hidden Tig Functions

    Hidden TIG functions There are hidden functions in the control panel. To access the functions, press for 5 seconds. The display shows a letter and a value. Select function by pressing the right arrow. The knob is used to change the value of the selected function.
  • Page 8: Symbol And Function Explanations

    (16) appearing in the display and welding cannot be started whilst the error message is displayed. Contact an authorised ESAB service technician to activate the function. Hidden MMA functions There are hidden functions in the control panel.
  • Page 9: Fault Codes

    Control panel TA23 Function Settings C = Arc Force 0 - 99 d = drop welding 0 = OFF; 1 = ON F = regulator type 1 = ArcPlust II; 0 = ArcPlust H = Hotstart 0 - 99 Arc force The arc force is important in determining how the current changes in response to a change in the arc length.
  • Page 10: Fault Code Descriptions

    The welding data unit has lost contact with the cooling unit. The welding process stops. Action: Check the wiring. Send for a service technician if the fault persists. ORDERING SPARE PARTS Spare parts may be ordered through your nearest ESAB dealer, see the last page of this publication. - 10 -...
  • Page 11: Ordering Number

    0460 032 190 Instruction manual LV 0460 032 191 Instruction manual SI 0460 032 192 Instruction manual LT 0459 839 003 Spare parts list Instruction manuals and the spare parts list are available on the Internet at www.esab.com - 11 - Edition 100702 bi15o...