6 GOUGING
6.1
Settings for gouging
Settings
Arc voltage *
Welding current *(CA)
Wire feed speed *(CW)
Travl speed *
Welding direction
Start data
Air pre-flow
Start adjust
Start type
Wire creep start
Wire creep start speed
Start phases
Open-circuit voltage
Maximum open-circuit voltage
Stop data
Air post-flow
Crater filling
Crater filling time
Burnback time
Stop phases
Dynamic regulation
Setting limits
Measure limits
*) The setting range is dependent on the product used.
0460 949 474
Setting range
14 -50 V
0 - 3200 A
0 - 2500 cm/min
0 - 200 cm/min
▲-■
0 - 99.0 s
Min = 50%
Direct or Scratch
Auto or Set speed
0 - 1000 cm/min
OFF or ON
OFF or ON
5 - 60 V
0 - 99.0 s
OFF or ON
0 - 10 s
0- 10 s
OFF or ON
Auto or Set values
-
-
- 24 -
In steps of
Value after
resetting
0.1 V (1V)
30 V
1 A
500 A
1 cm/min
100 cm/min
1 cm/min
30 cm/min
-
■
0.1 s
0 s
1%
100%
-
Direct
-
Auto
1 cm/min
20 cm/min
-
OFF
-
OFF
0.1 V
50 V
0.1 s
0 s
-
OFF
0.01 s
0.0 s
0.01 s
1.50 s
-
OFF
-
Auto
-
-
-
-
© ESAB AB 2021