4 GAS METAL ARC WELDING
Settings
Crater filling time
Burnback time
Stop phases
Dynamic regulation
Setting limits
Measure limits
*) The setting range is dependent on the product used.
0460 949 474
Setting range
In steps of
0 - 10 s
0.01 s
0- 10 s
0.01 s
OFF or ON
-
Auto or Set values -
-
-
-
-
- 20 -
Value after
resetting
0.0 s
0.20 s
OFF
Auto
-
-
© ESAB AB 2021