Active Errors; Unit Ids; Description Of Fault Management Codes - ESAB A2 PEK Instruction Manual

Hide thumbs Also See for A2 PEK:
Table of Contents

Advertisement

10 TOOLS
The unit in which the error has occurred, see section "Unit IDs"
The error's error management code, see section "Description of fault management
codes"
ERROR LOG
Index
1
2
3
DELETE ALL
10.1.2

Active errors

MAIN MENU » TOOLS » EVENT HANDLING » ACTIVE ERRORS
The Active errors menu shows only the errors active for the moment.
ACTIVE ERRORS
Error nr
78
152
10.1.3

Unit IDs

Explanation of unit IDs for LAF and TAF power source:
   2   = Power source
   6   = Wire feed and travel motion (motor board)
   8   = Control panel
NOTE!
The unit IDs specified above apply to LAF and TAF power sources, and constitutes an
example of unit IDs for Aristo® 1000, as the nodes in an Aristo® 1000 application
may have different ID numbers depending on the configuration of the equipment.
10.1.4

Description of fault management codes

The fault management codes that users can correct themselves are given below. If another
code appears, restart the machine and if the error persists, contact a service technician.
  6
  High temperature
The power source has overheated. Welding is cancelled. Welding is permitted again when the
temperature falls below the maximum temperature parameter.
1.
Check that the cooling air inlets or outlets are not obstructed or clogged with dirt.
2.
Check the duty cycle being used, to make sure that the equipment is not being overloaded.
0460 949 474
Date
Time
081120
11:24:13
081120
10:24:18
081121
13:24:18
Error in battery-driven memory
Node ID
1
1
Error nr 78
- 60 -
Unit
8
8
8
 
 
 
Error
19
18
17
QUIT
Device type
powersource
powersource
QUIT